Verwenden Sie den Reader unten, um das Fetco CBS-52H-15 Kaffeemaschine Bedienungsanleitung zu lesen. Sie können die Anleitungen direkt auf der Seite durchblättern und die Funktionen unseres Readers nutzen, um alle wichtigen Informationen zur Installation, Bedienung und Wartung dieser Fetco Kaffeemaschine zu finden.
Bedienungsanleitung
VollbildFehlerbehebung
Praktische Tipps zur Lösung der häufigsten Probleme mit Fetco CBS-52H-15.
Ursache: Power switch off
Turn switch on
Ursache: No power to the brewer (Brewer lights are not illuminated)
Make sure the brewer is plugged in. Check the wall circuit breaker / reset. Turn the brewer power switch off then back on (it has an internal breaker)
Ursache: Bad timer or dispense latch assembly
Check for voltage reaching the timer from the dispense latch assembly. If yes replace timer. If no, replace latch assy
Ursache: Bad dispense latch assembly
Replace the dispense latch assembly
Ursache: Bad dispense latch assembly
Replace the dispense latch assembly
Ursache: No water reaching the brewer
Make sure the shut off valve is open. Check water line for kinks; replace line if necessary. Check to see if filter is clogged by changing it
Ursache: Flow discs in spray heads in upside down with flange on flow disc facing wrong direction
Reassemble spray heads - bumps on spray cutter face with flange on flow disc facing correct direction
Ursache: Water filter clogged
Replace water filter
Ursache: Spray head clogged
Clean and or replace the sprayhead
Ursache: Timer/s are set too low
Advance timers to proper level
Ursache: Incoming Voltage is too low for timers to function at proper time sequences
Reset wall circuit breaker as one side may drop out & not flag the breaker. Call an electrician to find loose connections in the building
Ursache: Water filter clogged
Replace water filter
Ursache: Weak dispense latch assembly (usually buzzes during cycle)
Replace dispense latch assembly
Ursache: Water pressure or flow rate is too low or fluctuates too much to support a full brew
Make sure brewer has a dedicated water line. Ensure that the shut off valve is open all the way (Never use needle saddle valves). Increase the diameter of the water line to the brewer and or find stable source
Ursache: Brewer is not level
With an accurate level, level the brewer front to back and left to right by adjusting the feet
Ursache: Timer/s are set too high
Adjust timers down to appropriate level
Ursache: Thermal server not empty
Empty the server and try again
Ursache: Unknown
Call FETCO Service Dept. to discuss. (800) 338-2699
Ursache: Spray head missing
Attach spray head assembly
Ursache: Improper dose
Measure and confirm correct dose
Ursache: Filter papers
Make sure only one paper is used
Ursache: Cracked dispense tube
See spray head drips MAJOR section
Ursache: Low brew temperature (Temperature inside the hot water tank is set to 205° F, the metal delivery system drops the temp)
Adjust thermostat so the water stream measured at the bottom of the brew basket, 1/3 of the way through the brew cycle, equals 190 degrees + or - 5 degrees
Ursache: Spray head missing
Replace spray head
Ursache: Half batch used incorrectly
Use smaller half batch brew basket. Discourage half batch use. Investigate the need for a smaller brewer
Ursache: Water Softener in use
Move brewer water feed to a non-softened source
Ursache: Extremely fresh coffee
Call FETCO Service Dept. to discuss. (800) 338-2699
Ursache: Bypass valve closed
Open bypass valve
Ursache: Flow disc wrong size or missing
Correct or replace flow disc
Ursache: Condensation around the sprayhead area
Wipe sprayhead area after brewing; place an empty container under brew cone when not in use
Ursache: Condensation from water tank dripping through dispense tube
Insert an empty brew basket and server under brew heads when not in use
Ursache: Cracked dispense tube/s (This problem starts out minor but gets steadily worse)
Replace both dispense tubes even if other side is not dripping
Ursache: Fill valve not sealing (Will drip even with power off)
See Brewer won't stop brewing section - Bad or stuck fill valve
Ursache: Dispense tube cracked
See sprayhead drips MAJOR section
Ursache: Mechanical binding
Re-align the brew handle / brass sprayhead tower / and dispense tube into a straight line by moving brass tower
Ursache: Water pressure over 75psi
Place a water pressure regulator on the line and reduce to 20-75 psi
Ursache: Dispense tube drive screw off. A 2.5 inch screw that connects the handle to the dispense tube at the brass sprayhead tower
Ensure that the drive screw is straight (can be straightened by hand while still in the brew handle) and reconnect to the dispense tube. The flange that the drive screw engages MUST be held flat against the brass sprayhead tower, without being able to back out
Ursache: Water level probe bad or encrusted with lime
Clean lime build up on the probe tip and/or tank wall. (Holding the probe wire (green) from the probe end to the body of the brewer should stop the fill if the probe is bad but the liquid level board is good)
Ursache: Bad liquid level control board
Replace the LLC board if grounding the probe end of the (green) probe wire to the body of brewer does not remove the voltage at the fill terminal on the LLC board
Ursache: Bad or stuck fill valve (it is not magnetic)
Rebuild or replace the fill valve if no voltage is on the coil and it still passes water to the tank. (Disconnect the outlet side to see if it leaks water to the tank)
Ursache: Incorrect dosage
Measure and confirm the correct amount of coffee required
Ursache: Short brew levels
See Short brew levels section
Ursache: No power to brewer
Make sure power switch is on. Reset machine circuit breaker. Check power connection. (plug or hard wire connection). Check building circuit breaker. (Always reset breaker by switching off, then on)
Ursache: Defective liquid level control board (No power to thermostat)
With power on, and water tank full, check LLC board for 120 volts on brown wire and neutral. Replace LLC board if there is no voltage
Ursache: Bad connections on solid state relay (No power to heaters)
Check relay for burned or loose connections. Replace with high temperature connectors if necessary
Ursache: Defective solid state relay (No power to heaters)
Check input and output voltages on relay. 120 volts on blue wire (input) but no voltage out to heaters indicates a bad relay
Ursache: Bad heating element/s
Check amperage draw on heater wires. 0 amps = bad heater
Ursache: Bad Thermostat (the thermostat believes that it is at set temperature)
Replace the thermostat and or thermal probe. It's not possible to trouble shoot the probe
Ursache: Low brew temperature setting on thermostat
See Low brew temperature under Weak Coffee section
Ursache: Brewers with more than one heater can have just one fail heater
Check amperage draw on heater wires. 0 amps = bad heater
Ursache: Hot water tank limed up
Remove access cover to the hot water tank and inspect for lime. Remove the brewer for shop de-liming if build up is thick
Ursache: Thermostat set too high for altitude (Denver etc)
Reduce temperature setting to 3 degrees below boiling at your altitude
Ursache: Defective thermostat
Replace the thermostat and or thermal probe. It's not possible to trouble shoot the probe
Hilfe
Hast du Fragen zur Kaffeemaschine CBS-52H-15 von Fetco? Stelle sie direkt unserem Experten! Du erhältst Informationen, praktische Tipps und maßgeschneiderte Lösungen in nur wenigen Sekunden.
Ähnliche Bedienungsanleitungen
Unten finden Sie Bedienungsanleitungen für Kaffeemaschine, die ähnlich wie CBS-52H-15 sind. Versuchen Sie auch, alle Fetco Kaffeemaschine Bedienungsanleitungen anzusehen
Diskussion
Hinterlassen Sie einen Kommentar oder stellen Sie eine Frage
An der Diskussion teilnehmen
Stellen Sie eine Frage zum Handbuch oder fügen Sie eine hilfreiche Antwort für andere Nutzer hinzu.