Verwenden Sie den Reader unten, um das Gree VIR12HP230V1AH Klimaanlage Bedienungsanleitung zu lesen. Sie können die Anleitungen direkt auf der Seite durchblättern und die Funktionen unseres Readers nutzen, um alle wichtigen Informationen zur Installation, Bedienung und Wartung dieser Gree Klimaanlage zu finden.
Bedienungsanleitung
VollbildFehlercodes
Nachfolgend finden Sie die Fehlercodes für den Gree VIR12HP230V1AH.
System Configuration C5 1) No jumper cap inserted on the control board. Malfunction 2) Incorrect or damaged jumper cap on control board.
System High Pressure E1 1) Over charged with refrigerant. 2) Blocked or dirty outdoor coil .
Indoor Anti-Freeze Protection E2 3 flashes 1) Low return airflow. and 2) Indoor fan speed is too low.
Compressor High Discharge E4 7 flashes Please refer to the malfunction analysis (discharge Temperature Protection and temperature, overload) in service manual.
Overcurrent Protection E5 5 flashes 1) Supply voltage is unstable. and 2) Supply voltage is too low and system load is too high.
Communication Malfunction E6 Continuous 1) Communication cable is mis-wired between indoor On and outdoor units.
High Temperature E8 6 flashes 1) Incorrect refrigerant charge level. Resistant Protection and 2) Refrigerant metering device malfunction.
Refrigerant Leakage Protection F0 9 flashes 1) refrigerant leak(s). and 2) Indoor coil temperature sensor no calibrated.
Indoor Ambient Temperature F1 1) Loose or bad connection between sensor and control board. Sensor Malfunction 2) Indoor ambient temperature sensor damaged.
Indoor Coil Temperature F2 1) Loose or bad connection between sensor and control board. Sensor Malfunction 2) Indoor coil temperature sensor damaged.
Outdoor Ambient Temperature F3 6 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Outdoor ambient temperature sensor damaged.
Outdoor Coil Temperature F4 5 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Outdoor coil temperature sensor damaged.
Outdoor Discharge Temperature F5 7 flashes 1) Loose or bad connection between sensor and control board. Sensor Malfunction and 2) Discharge temperature sensor damaged.
Compressor Overload Protection H3 8 flashes 1) Wiring terminal OVC-COMP is loose. and 2) Refer to the malfunction analysis in Service Manual.
High DC Bus Voltage Protection PH 13 flashes 1) Supply voltage on L1 and N is above 265Vac. and 2) Capacitor on control board malfunction.
Compressor Phase Current P5 1) IPM module malfunction. Protection 2) Outdoor control board malfunction
Module Temperature Sensor P7 Outdoor control board malfunction Malfunction
Module Temperature Protection P8 1) Lack of thermal grease on IPM module. 2) Heat sink (radiator) not tightly mounted.
Hilfe
Hast du Fragen zur Klimaanlage VIR12HP230V1AH von Gree? Stelle sie direkt unserem Experten! Du erhältst Informationen, praktische Tipps und maßgeschneiderte Lösungen in nur wenigen Sekunden.
Ähnliche Bedienungsanleitungen
Unten finden Sie Bedienungsanleitungen für Klimaanlage, die ähnlich wie VIR12HP230V1AH sind. Versuchen Sie auch, alle Gree Klimaanlage Bedienungsanleitungen anzusehen
Diskussion
Hinterlassen Sie einen Kommentar oder stellen Sie eine Frage
An der Diskussion teilnehmen
Stellen Sie eine Frage zum Handbuch oder fügen Sie eine hilfreiche Antwort für andere Nutzer hinzu.