Verwenden Sie den Reader unten, um das Perlick Signature Series HP48WW-S-3-2L-2R Kühlschrank Bedienungsanleitung zu lesen. Sie können die Anleitungen direkt auf der Seite durchblättern und die Funktionen unseres Readers nutzen, um alle wichtigen Informationen zur Installation, Bedienung und Wartung dieser Perlick Kühlschrank zu finden.
Bedienungsanleitung
VollbildFehlercodes
Nachfolgend finden Sie die Fehlercodes für den Perlick Signature Series HP48WW-S-3-2L-2R.
Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes
Make sure the door is completely closed. Check the door gasket seal and replace if necessary. Check the condenser and clean it if necessary. Make sure the louvered plate is unobstructed. Make sure the interior light is off. Wait 24 hours if warm product was recently placed in the cabinet.
Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes
Make sure the door is completely closed. Check the door gasket seal and replace if necessary. If surrounding ambient temperature has recently changed dramatically, the compartment temperature may be affected.
Thermostat probe has failed
Contact Perlick Technical Service at 800-558-5592
Evaporator probe has failed
Contact Perlick Technical Service at 800-558-5592
Fehlerbehebung
Praktische Tipps zur Lösung der häufigsten Probleme mit Perlick Signature Series HP48WW-S-3-2L-2R.
Ursache: Bulb is loose or burnt out
Tighten bulb or replace bulb
Ursache: Manual switch is on or door is not making contact with the door switch
Turn manual switch off or make sure the door closes tightly
Ursache: LED board failure
Contact Perlick Technical Service at 800-558-5592
Ursache: Soft sounds from compressor, fan motor and valves or crackling sound during defrost
This is normal operation
Ursache: No power is going to the unit or condenser is dirty
Reset the circuit breaker, turn on the ON/OFF keypad, check the Dual-Zone power switch if applicable, or clean the condenser
Ursache: Control preset is set to warm, light is staying on, condenser is dirty or obstructed, door is open frequently, louvers and/or fan guard is obstructed, or warm product was recently placed
Lower the setpoint temperature, turn off manual light switch, clean the condenser, close the door, make sure louvers and fan are not obstructed, or wait 24 hours for product to chill
Ursache: Condenser is dirty or obstructed, door was kept open, or warm product was recently placed in the cabinet
Clean the condenser and clear obstruction, wait 24 hours and recheck temperature
Ursache: High humidity and/or frequent door opening or door is not closing and sealing properly
This is normal operation in high humidity. Make sure the door is closing properly and check the door seal. Replace if necessary. If condensation persists, contact Perlick Technical Service at 800-558-5592
Häufig gestellte Fragen
Die häufigsten Fragen zum Perlick Signature Series HP48WW-S-3-2L-2R.
Hilfe
Hast du Fragen zur Kühlschrank Signature Series HP48WW-S-3-2L-2R von Perlick? Stelle sie direkt unserem Experten! Du erhältst Informationen, praktische Tipps und maßgeschneiderte Lösungen in nur wenigen Sekunden.
Ähnliche Bedienungsanleitungen
Unten finden Sie Bedienungsanleitungen für Kühlschrank, die ähnlich wie Signature Series HP48WW-S-3-2L-2R sind. Versuchen Sie auch, alle Perlick Kühlschrank Bedienungsanleitungen anzusehen
Diskussion
Hinterlassen Sie einen Kommentar oder stellen Sie eine Frage
An der Diskussion teilnehmen
Stellen Sie eine Frage zum Handbuch oder fügen Sie eine hilfreiche Antwort für andere Nutzer hinzu.